Skip to content

List of Boilers~

This is the current list of supported boilers from brands like Buderus, Nefit, Sieger, Junkers and Bosch:

  • BK13, BK15
  • GB125, GB135, GB1x2i, GB162, GBx72, GB212, GB162, GB192, GB122, GB192i.2
  • MC10
  • Cascade CM10, MC400
  • Logano
  • Logamax Plus GB022, U122
  • Logamatic MC10, MC110
  • Condens 2500, GC9000
  • Logomatic
  • Cerapur Top, Aero
  • Greenstar Si, 30Ri Compact, ErP, HIU, 8000
  • Nefit Topline, Trendline
  • Cascade MCM10
  • Nefit Proline
  • Nefit Smartline
  • GC7000F, GC9800IW
  • KB195i
  • Hybrid Heatpump
  • Enviline
  • Compress 6000AW
  • Hybrid 3000-7000iAW
  • SupraEco
  • WLW196i, WSW196i
  • Condens 2300, 5000i
  • Ecomline Excellent
  • EasyControl Adapter

Device Entities~

Notice

The boiler commands below will vary depending on boiler type/brand and system configuration Some commands will not work because they are overwritten by controller or thermostat. In this case there are thermostat commands for this setting.

this list is not complete and subject to change between versions

command data id comments
comfort <hot \|eco \| intelligent>
flowtemp <degrees> Limited to heatingtemp, set by thermostat if present
wwsettemp <degrees> Only if thermostat does not manage it
boilhyston <degrees> Start burner below flowtemp (negative value), allowed range depends on boiler type
boilhystoff <degrees> Stop burner above flowtemp (positive value), allowed range depends on boiler type
burnperiod <minutes>
burnminpower <%> Changeable only for modulated burners
burnmaxpower <%> Changeable only for modulated burners
pumpdelay <minutes>
wwactivated <off \| on>
wwtapactivated <off \| on> Special function working in boiler test-mode
wwonetime <off \| on> Overwritten by some thermostats, see thermostat commands
wwcircpump <off \| on>
wwcirc <off \| on> Overwritten by some thermostats, see thermostat commands
wwcircmode <n> (1=1x3min, .. 6=6x3min, 7=on)
wwflowtempoffset <degrees> Offset to boiler temperature while preparing warm water
wwmaxpower <%> Maximum power for warm water heating
heatingactivated <off \| on> Not changeable for some systems. i.g. Set by MC10 rotary control
heatingtemp <degrees> Upper limit for flowtemp, not changeable for some systems or overwritten (MC10)
maintenance <off \| <hours> \| <dd.mm.yyyy> \| reset> set maintenance to date or time or reset message
pumpmodmin <%> Changeable only for modulated pumps
pumpmodmax <%> Changeable only for modulated pumps
reset <error \| maintenance> Use reset error only if there is an active error!