List of Boilers~
This is the current list of supported boilers from brands like Buderus, Nefit, Sieger, Junkers and Bosch:
- BK13, BK15
- GB125, GB135, GB1x2i, GB162, GBx72, GB212, GB162, GB192, GB122, GB192i.2
- MC10
- Cascade CM10, MC400
- Logano
- Logamax Plus GB022, U122
- Logamatic MC10, MC110
- Condens 2500, GC9000
- Logomatic
- Cerapur Top, Aero
- Greenstar Si, 30Ri Compact, ErP, HIU, 8000
- Nefit Topline, Trendline
- Cascade MCM10
- Nefit Proline
- Nefit Smartline
- GC7000F, GC9800IW
- KB195i
- Hybrid Heatpump
- Enviline
- Compress 6000AW
- Hybrid 3000-7000iAW
- SupraEco
- WLW196i, WSW196i
- Condens 2300, 5000i
- Ecomline Excellent
- EasyControl Adapter
Device Entities~
Notice
The boiler commands below will vary depending on boiler type/brand and system configuration Some commands will not work because they are overwritten by controller or thermostat. In this case there are thermostat commands for this setting.
this list is not complete and subject to change between versions
command | data | id | comments |
---|---|---|---|
comfort | <hot \|eco \| intelligent> | ||
flowtemp | <degrees> | Limited to heatingtemp, set by thermostat if present | |
wwsettemp | <degrees> | Only if thermostat does not manage it | |
boilhyston | <degrees> | Start burner below flowtemp (negative value), allowed range depends on boiler type | |
boilhystoff | <degrees> | Stop burner above flowtemp (positive value), allowed range depends on boiler type | |
burnperiod | <minutes> | ||
burnminpower | <%> | Changeable only for modulated burners | |
burnmaxpower | <%> | Changeable only for modulated burners | |
pumpdelay | <minutes> | ||
wwactivated | <off \| on> | ||
wwtapactivated | <off \| on> | Special function working in boiler test-mode | |
wwonetime | <off \| on> | Overwritten by some thermostats, see thermostat commands | |
wwcircpump | <off \| on> | ||
wwcirc | <off \| on> | Overwritten by some thermostats, see thermostat commands | |
wwcircmode | <n> | (1=1x3min, .. 6=6x3min, 7=on) | |
wwflowtempoffset | <degrees> | Offset to boiler temperature while preparing warm water | |
wwmaxpower | <%> | Maximum power for warm water heating | |
heatingactivated | <off \| on> | Not changeable for some systems. i.g. Set by MC10 rotary control | |
heatingtemp | <degrees> | Upper limit for flowtemp, not changeable for some systems or overwritten (MC10) | |
maintenance | <off \| <hours> \| <dd.mm.yyyy> \| reset> | set maintenance to date or time or reset message | |
pumpmodmin | <%> | Changeable only for modulated pumps | |
pumpmodmax | <%> | Changeable only for modulated pumps | |
reset | <error \| maintenance> | Use reset error only if there is an active error! |